UC-500 and UC-501 Design Considerations
Recent construction trends have shown an increased popularity in the use of concealed fastener wall panel systems. Due to this increased popularity, both the UC-500 and UC-501 have been used more frequently as an option when vertical concealed fastener wall panels are specified. As both the UC-500 and UC-501 panel systems were originally designed for use as linear soffit panel systems, complications can and do arise in the application of these panels on a vertical wall surface. The appropriate time to address the panel characteristics, aesthetic expectations, design considerations, application and installation tolerances is prior to bidding the project.
Please consult the UC-500 and UC-501 Wall Panel Design Consideration Guide for additional information regarding:
- Aesthetic expectations and design considerations
- Installation tolerances
- Joint support spacing
- Engineered connections
- Support framing tolerances
- Panel installation
- Handling
- Galvanic reaction
- Installing screws
- Joint sealant
- UC-500 panel loads and stitch fasteners
- UC-501 panel loads and exposed fasteners
- Reverse panel install
- Stiffing ribs
- Embossing
- Oil canning causes and prevention (Not a cause for rejection)
- Misalignment of the support system
- Over engagement of panels
- Over driving of fasteners
- Longitudinal expansion
- Handling
- Design
- Panel width
- Installation
- Handling
- Gauge