Test Protocol / Code Approval / System Group
| ASTM E 283 | ASTM E 330 | ASTM E 331 | AAMA 501 | AAMA 508 | ASTM 1592 | ASTM 1680 | ASTM 1646 | Miami Dade NOA | Florida Building Code | Barrier System | Rain Screen System | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Series 10 | ![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
||||||
| Series 1000 UC* | ![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
|||||
| Series 1200 | ![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
|||||
| Series 1500 | ![]() |
![]() |
![]() |
![]() |
![]() |
|||||||
| Series 2000 | ![]() |
![]() |
![]() |
![]() |
![]() |
|||||||
| Series 2500 | ![]() |
![]() |
![]() |
![]() |
![]() |
|||||||
| Series 3000 UC* | ![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
|||||
| Series 3200** | ![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
||||||
| Series 4000 | ![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
|||||
| Series 4500 | ![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
|||||
| UC 500 | ![]() |
![]() |
![]() |
![]() |
![]() |
|||||||
| VR Panel | ![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
||||
| UR Panel | ![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
||||
| HR Panel | ![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
||||
| Flat-Lock | ![]() |
![]() |
![]() |
![]() |
![]() |
Notes:
* Miami Dade NOA testing for Series 1000 UC and 3000 UC was conducted on a mechanically attached clip and each UNA-CLIP project will require a technical review to ensure the proper clip is utilized.
** No separate AAMA 508 testing was conducted for Series 3200. The Series 3200 system is identical to the Series 1200 but with a different exterior skin material.
Air Infiltration = ASTM E 283 "Standard Test Method for Rate of Air Leakage Through Exterior Wall"
Air Infiltration = ASTM E 1680 is a open purlin test
Water Resistance = ASTM E 331 "Test Method for Water Penetration of Exterior Wall"
Water Resistance = ASTM 1646 is a open purlin test
Structural Load = ASTM E 330 "Standard Test Method for Structural Performance of Exterior Wall"
Structural Load = ASTM 1592 is a open purlin structural test
Wind Driven Rain = AAMA 501 "Standard Test Method for Water Penetration"
Miami Dade Notice of Acceptance Testing
Requires TAS 201 (Large Missile Impact), TAS 202 (Water Resistance), TAS 203 (Cyclic Wind Pressure) & ASTM E8-04 (Tensile)